PNI Sensor Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261
For the most current specifications, please visit our website at: www.pnicorp.com DOC # 1011946 R07
21-Jan-11 Page 8 of 16-
MS2100
Specifications & Instructions
OPERATION
Basic operation will follow these steps. Refer to Figure 2 and Figure 3.
1. SSNOT is brought low.
2. Pulse RESET high (return to low state). You must RESET the MS2100 before every
measurement.
3. Data is clocked in on the MOSI line. Once eight bits are read in, the MS2100 will execute the
command.
4. The MS2100 will make the measurement. A measurement consists of forward biasing the sensor
and making period count; then reverse biasing the sensor and counting again; and finally, taking
the difference between the two bias directions.
5. At the end of the measurement, the DRDY line is set to high indicating that the data is ready. In
response to the next 16 SCLK pulses, data is shifted out on the MISO line.
If you need to make another measurement, go to Step 2. You can send another command after the reset. In
this case, keep SSNOT low. If you will not be using the MS2100, set SSNOT to high to disable the SPI
port.
Figure 2: SPI Port Full Timing Sequence (cpol=0)
Figure 3: SPI Port Timing Parameters (cpol = 0)