Pni MS2100 Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
PNI Sensor Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261
For the most current specifications, please visit our website at: www.pnicorp.com DOC # 1011946 R07
21-Jan-11 Page 10 of 16-
MS2100
Specifications & Instructions
Command Byte
The operation of the MS2100 is controlled by the data received into the SPI port. The command byte
syntax is as follows:
Table 7: Command Byte Syntax
Position
7
6
5
4
3
2
1
0
Bit
DHST
PS2
PS1
PS0
ODIR
MOT
ASI
ASO
RESET
0
0
0
0
0
0
0
0
DHST High Speed Oscillator Test
When high, the internal high speed clock is set to drive the DHST pad at ½ the clock speed.
When low, the DHST pad is set to DVDD. This is used for debug purposes only, and will not be
set in normal operation.
PS0, PS1, and PS2 Period Select
Selects the division ratio applied to the L/R oscillator output to set the period being measured.
Table 8: Period Select Division Ration
PS2
PS1
PS0
Ratio
0
0
0
/32
0
0
1
/64
0
1
0
/128
0
1
1
/256
1
0
0
/512
1
0
1
/1024
1
1
0
/2048
1
1
1
/4096
ODIR Oscillator Direction
Determines the magnetic oscillator direction if MOT is set to 1. It has no effect on direction when
the MOT bit is set to zero. This is used for debug purposes only, and will not be set in normal
operation.
MOT Magnetic Oscillator Test
When set, causes the magnetic oscillator selected by AS0 and AS1 in the directions
selected by ODIR to run continuously until MS2100 is reset.