Pni Legacy Comm Board Manuel d'utilisateur Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
PNI Corporation 133 Aviation Blvd., Suite 101, Santa Rosa, CA 95403-1084 USA;, Fax: (707) 566-2261
For the most current specifications, please visit our website at: www.pnicorp.com
Page 9 of 42
Raw Output Mode (sdo=r)
The Raw Output mode allows for the output of the raw, uncorrected data for any or all of the
required sensors. The Raw Output Mode is the only mode where Z-Axis is active.
EXAMPLE:
$raw,X53Y-420Z0*6E
$raw,{data}*<dcs><es>
Table 10: Raw Output Modes
$ Start data delimiter
{data} Selected data output
* End data delimiter
<dcs> Checksum
<es> End of message based on eol variable <cr> or <lf> or <cr><lf>
NOTE: For modules with a Z-axis when used in other modes than raw, Z-axis is turned off and module
is run as a Z-axis system since no tilt compensation is being done.